MiniAir mini ATEX 20 m/s (vane and handle in aluminium)
Product number:
SW10019.1
Product information "MiniAir mini ATEX 20 m/s (vane and handle in aluminium)"
MiniAir mini ATEX plastic/alu
Classification II 2G EEx ia IIC T6 / I M2 EEX ia IThe mini ATEX probe made of plastic and aluminium is suitable to use it in the environment explosive substances.
There are two different flow measuring ranges 0,4 to 20 m/s and 0,5 to 40 m/s.
With a measuring accuracy of the flow of 1,0 % F.S. and 1,5 % o.r. is the use of a vane anemometer most exact measurement method.
With an accuracy of +/-0,5°C is this probe able to measure temperatures from -20 to +140°C
and you can use it in temperatures from -30 to +140°C.
The cable is 2 m long and can be exposed to temperatures of 80 to 85°C.
With the following measurements the mini is our middle snap head:
head diameter 22 x 28 mm; probe length 175 mm
The probe should be stored in temperatures from -65 to +150°C.
By the snap head principle the probe is useable for a non stop operation and you can easily change the head.
MiniAir mini ATEX stainless steel to 140°C
The mini ATEX probe made of stainless steel is suitable to use it in the environment of explosive substances .
There are two different flow measuring ranges 0,7 to 20 m/s and 0,8 to 40 m/s.
With a measuring accuracy of the flow of 1,0 % F.S. and 2,0 % o.r. is the use of a vane anemometer most exact measurement method. With an accuracy of +/-0,5°C is this probe able to measure temperatures from -20 to +140°C
and you can use it in temperatures from -30 to +140°C.
The cable is 2 m long and can be exposed to temperatures of 80 to 85°C.
With the following measurements the mini is our middle snap head:
head diameter 22 x 28 mm; probe length 182 mm
The probe should be stored in temperatures from -65 to +150°C.
If required the head can be replaced by us.
MiniAir mini ATEX stainless steel to 250°C
Classification II 2G EEx ia IIC T6 / I M2 EEX ia IThe mini ATEX probe made of stainless steel is suitable to use it in the environment explosive substances .
There are two different flow measuring ranges 0,7 to 20 m/s and 0,8 to 40 m/s.
With a measuring accuracy of the flow of 1,0 % F.S. and 2,0 % o.r. is the use of a vane anemometer most exact measurement method. This probe does not have a temperature measurement.
The probe is usable in temperatures from -30 to +250°C
and the external electronic system in temperatures up to 65°C.
The cable is 2,4 m long (1,5 m from the external electronic system)
and can be exposed to a temperatures of 250°C.
With the following measurements the mini is our middle snap head:
head diameter 22 x 28 mm; probe length 182 mm
The probe should be stored in temperatures from -65 to +250°C.
The external electronic system and the cable should be stored in temperatures to max. 65°C.
If required the head can be replaced by us.