MiniAir6 micro 40 m/s ATEX (vane and handle in alu)

SFR 3,240.00*

Measuring range
Vane and handle material
Product number: SW10055.2
Product information "MiniAir6 micro 40 m/s ATEX (vane and handle in alu)"
Process measuring device - voltage signal

MiniAir6 micro ATEX plastic/alu
Classification II 2G EEx ia IIC T6 / I M2 EEX ia I

The MiniAir6 ATEX made of aluminium and plastic is suitable to use it in the environment of explosive/inflammatory substances.
There are two different flow measuring ranges 0,6 to 20 m/s and 0,7 to 40 m/s.
With a measuring  accuracy of the flow of 1,0 % F.S. and 3,0 % o.r. is the use of a vane anemometer most exact measurement method.
The probe is usable in temperatures from -10 to +100°C.
You need an external input of 9 to 26 V DC for the electricity supply.
The probe has an output signal of 0 to 2,0 V.
It is possible to expose the MiniAir6 with a load of the external device of 10 kΩ .
The cable is 5 m long.

With the following measurements the micro is our smallest snap head:
head diameter 11 x 15 mm; access opening 16 mm;  probe length 165 mm
The probe should be stored in temperatures from -65 to +150°C.

Because of the snap head principle our probes are useable for a non-stop operation and the head is easily changeable.

MiniAir6 micro ATEX steel
Classification II 2G EEx ia IIC T6 / I M2 EEX ia I

The MiniAir6 ATEX made of stainless steel is suitable to use it in the environment of explosive/inflammatory substances.
There are two different flow measuring ranges 1,0 to 20 m/s and 1,3 to 40 m/s.
With a measuring  accuracy of the flow of 1,5 % F.S. and 3,5 % o.r. is the use of a vane anemometer most exact measurement method.
The probe is usable in temperatures from -10 to +100°C.
You need an external input of 9 to 26 V DC for the electricity supply.
The probe has an output signal of 0 to 2,0 V.
It is possible to expose the MiniAir6 with a load of the external device of 10 kΩ .
The cable is 5 m long.

With the following measurements the micro is our smallest probe head:
head diameter 11 x 15 mm; access opening 16 mm;  probe length 165 mm
The probe should be stored in temperatures from -65 to +150°C.

If required the head can be replaced by us.