Welcome to TSR Messtechnik AG,
Your ISO/IEC 17025:2018 accredited specialist for precise vane anemometers, differential pressure measurement sensors, tunnel measurement systems and individual measurement solutions from Switzerland!
Our mobile solutions
Measurement with impeller (air 0 - 40 m/s)
Application: Air outlets, ventilation ducts, disk valves, ventilation grilles, swirl outlets, laboratory measurements
Plastic versions for temperatures from -30 °C to +80 °C, steel sensors for temperatures up to 250 °C
Integrated temperature measurement
MiniAir micro
No prices for category and customer group
MiniAir Micro plastic/aluminum up to 80°C / non-aggressive gases
Flow measuring ranges: 0.6 - 20 m/s or 0.7 - 40 m/s
Measuring accuracy: 1.0 % f.s. and 1.5 % f.s.
Operating temperature: -30 to 80ºC
Temperature measurement with accuracy of +/-0.5°C
Cable length: 2 m
Head diameter 11 x 15 mm; insertion opening 16 mm; sensor length 165 mm
Thanks to the renowned snap-on head principle, the sensors are suitable for continuous operation. The measuring head can be replaced in just a few simple steps.
MiniAir Micro steel up to 140°C / aggressive gases
Flow measuring ranges: 1.0 - 20 m/s or 1.3 - 40 m/s
Measuring accuracy: 1.5 % f.s. and 3.5 % f.s.
Operating temperature: -30 to 140ºC
Temperature measurement with accuracy of +/-0.5°C
Cable length: 2 m
Head diameter 11 x 15 mm; insertion opening 16 mm; sensor length 165 mm
The associated five-wire cable has a length of 2 m and can be exposed to temperatures between 80 and 85°C. The probe heads can be replaced if necessary.
MiniAir Micro steel up to 250°C / aggressive gases
Flow measuring ranges: 1.0 - 20 m/s or 1.3 - 40 m/s
Measuring accuracy: 1.5 % f.s. and 3.5 % f.s.
Operating temperature: -30 to 250ºC / associated evaluation box (external electronics) up to 65°C. Cable length: 2.4 m from external electronics, 1.5 m to external electronics
Head diameter 11 x 15 mm; retraction opening 16 mm; sensor length 165 mm
The associated five-wire cable from the external electronics has a length of 2.4 m and can withstand a temperature of up to 65°C. The probe heads can be replaced if necessary.
No prices for category and customer group
MiniAir mini
No prices for category and customer group
MiniAir Mini plastic/aluminum up to 80°C / non-aggressive gases
Flow measuring ranges: 0.4 - 20 m/s or 0.5 - 40 m/s
Measuring accuracy: 1.0 % f.s. and 1.5 % f.s.
Operating temperature: -30 to 80ºC
Temperature measurement with accuracy of +/-0.5°C
Cable length: 2 m
Head diameter 22 x 28 mm; insertion opening 35 mm; probe length 175 mm
Thanks to the renowned snap-on head principle, the sensors are suitable for continuous operation.
The measuring head can be replaced in just a few simple steps.
MiniAir Mini steel up to 140°C / aggressive gases
Flow measuring ranges: 0.7 - 20 m/s or 0.8 - 40 m/s
Measuring accuracy: 1.0 % f.s. and 2.0 % f.s.
Operating temperature: -30 to 140ºC
Temperature measurement with accuracy of +/-0.5°C
Cable length: 2 m
Head diameter 22 x 28 mm; insertion opening 35 mm; sensor length 175 mm
The associated five-core cable has a length of 2 m and can be exposed to temperatures between 80 and 85°C.
The probe heads can be replaced if necessary.
MiniAir Micro steel up to 250°C / aggressive gases
Flow measuring ranges: 0.7 - 20 m/s or 0.8 - 40 m/s
Measuring accuracy: 1.0 % f.s. and 2.0 % f.s.
Operating temperature: -30 to 250ºC / associated evaluation box (external electronics) up to 65°C.
Cable length: 1.5 m from external electronics, 2.4 m to external electronics
Head diameter 22 x 28 mm; retraction opening 35 mm; sensor length 175 mm
The associated five-wire cable from the external electronics has a length of 2.4 m and can withstand a temperature of up to 65°C.
No prices for category and customer group
MiniAir macro
No prices for category and customer group
MiniAir Macro plastic/aluminum up to 80°C / non-aggressive gases
Flow measuring ranges: 0.2 - 20 m/s or 0.3 - 40 m/s
Measuring accuracy: 1.0 % f.s. and 1.5 % f.s.
Operating temperature: -30 to 80ºC
Temperature measurement with accuracy of +/-0.5°C
Cable length: 2 m
Head diameter 80 x 85 mm; probe length 235 mm
Thanks to the renowned snap-on head principle, the sensors are suitable for continuous operation.
The measuring head can be replaced in just a few simple steps.
MiniAir Macro brass/ aluminum up to 140°C / aggressive gases
Flow measuring ranges: 0.2 - 20 m/s or 0.3 - 40 m/s
Measuring accuracy: 1.0 % f.s. and 1.5 % f.s.
Operating temperature: -30 to 140ºC
Temperature measurement with accuracy of +/-0.5°C
Cable length: 2 m
Head diameter 80 x 85 mm; sensor length 235 mm
The associated five-core cable has a length of 2 m and can be exposed to temperatures between 80 and 85°C. The impeller can be replaced if necessary.
No prices for category and customer group
Measurement with impeller (water 0 - 10 m/s)
For flow measurement in water.
MiniWater micro
No prices for category and customer group
MiniWater Micro plastic/aluminum up to 80°C
Flow measuring ranges: 0.04 - 5 m/s or 0.05 - 10 m/s
Measuring accuracy: 2.0 % f.s. and 3.5 % f.s.
Operating temperature: -30 to 80ºC
Temperature measurement with accuracy of +/-0.5°C
Cable length: 5 m
Head diameter 11 x 15 mm; insertion opening 16 mm; sensor length 165 mm
Thanks to the renowned snap-on head principle, the sensors are suitable for continuous operation.
The measuring head can be replaced in just a few simple steps.
No prices for category and customer group
MiniWater mini
No prices for category and customer group
MiniWater Micro plastic/aluminum up to 80°C
Flow measuring ranges: 0.02 - 5 m/s or 0.03 - 10 m/s
Measuring accuracy: 2.0 % f.s. and 3.0 % f.s.
Operating temperature: -30 to 80ºC
Temperature measurement with accuracy of +/-0.5°C
Cable length: 5 m
Head diameter 22 x 28 mm; insertion opening 35 mm; sensor length 175 mm
Thanks to the renowned snap-on head principle, the sensors are suitable for continuous operation.
The measuring head can be replaced in just a few simple steps.
No prices for category and customer group
Absolute and differential pressure
The ManoAir 4.0 is suitable for measuring absolute and differential pressure and is used in process, process and medical technology, in plant construction and power, gas and waterworks, in waste incineration and HVAC systems, mechanical engineering, chemical and petrochemical industries , Automotive industry.
The manometer can be equipped with two pressure modules to cover different measuring ranges:
Measuring range +/- 2000 Pa
Measuring range +/- 20 kPa
MC 4.0 ManoAir
No prices for category and customer group
The ManoAir 4.0 is suitable for measuring absolute and differential pressure and is used in process, process and medical technology, in plant construction and power, gas and waterworks, in waste incineration and HVAC systems, mechanical engineering, chemical and petrochemical industries , Automotive industry.The manometer can be equipped with two pressure modules to cover different measuring ranges:Measuring range +/- 2000 Pa, Resolution 0.1 Pa, measuring accuracy +/- 1 PaMeasuring range +/- 20 kPa, Resolution 0.1 kPa, measuring accuracy +/- 0.05 Pa• Selectable units of measurement for pressure: Pa / kPa, mbar, mmH2O• Display of rate of flow in m/s per keystroke• Mean, minimum and maximum values per keystroke• Automatic temperature compensation of the pressure sensor• Logger function as standardConnections:Pressure connections: push-on nipple for 3 mm int. dia. hose & 2 USB -C connectionsDisplay 3,2" TFT-Display, optional with Touch-Funktion (resistive)Measuring rate 2 measures / sPower Supply Lithium-Polymer-BatteryOperating life per battery charge approx. 15 hours (4000mAh)Housing dimensions (LxWxH)168 x 68 x 38 mmProtection IP 67Weight approx. 300 grammOperating temperature 0 to 60 °CHumidity 0 to 99 % rHProtection case Removable rubber case in blue, red, green and orange Overload capacity: 0.675 bar without ventilation,Pressure connections: push-on nipple for 3 mm int. dia. hoseMeasuring media: dry instrument air or inert gasesUnits of measurement: Pressure: Pa / kPa, mbar, mmH2O: Flow: m/sMeasuring rate: 2 measurements / sec.Working standard: Betz Micromanometer at 22ºC / 960 hPa
No prices for category and customer group
Prandtl tube
No prices for category and customer group
Ideal for temperatures up to 350° Celsius.Depending on size in made in Steel or nickeled Brass.
No prices for category and customer group
Case for instruments
No prices for category and customer group
Case for instruments (ideal for MC 4.0 incl. probes and extension rods).Dimensions outside [W x H x D] in mm 238 x 188 x 54Dimensions inside [W x H x D] in mm 223 x 140 x 41
No prices for category and customer group
Thermoelectric Anemometer
our specialist instrument for measuring very small air flow rates and determining degree of turbulence, as well as for humity measurements.
MC 4.0 ThermoAir
No prices for category and customer group
The handheld meter is designed for the measurement of very small air flowand the determination of the degree of turbulence, as well as for humidityand temperature measurement.Incl. logger function (up to 1.000.000 measurements) and the possibility toconnect 2 sensors. (Multichannel coming soon: Connect 4 or more probes)Measuring units airflow:m/s, km/h, ft/s, mphVolume flow: m³/h, l/min, m³/s, cfmHumidity: % rHTemperature: °C, °F, °KResolution: 0.01 Airflow / Volumeflow 0.1% rH / 0.1 °C /°F TemperatureDisplay: TFT display, optionally with touch functionMeasuring rate2 measurements/sPower supplyLi-Po battery 4000 mAhHousing dimensions: 168 x 68 x 38 mmWeight: approx. 300 grams
No prices for category and customer group
ThermoAir 4 directional
No prices for category and customer group
Flow measuring ranges:0.015 to 1 m/sor 0.015 to 5 m/sHead size: 8 mmShaft: 15 mmProbe length: 300 mmAngle of flow: +/- 30°Cable length: 1.5 m (more on requ.)Measurement accuracies:1 m/s 1.0% F.S. and 1.5% o.r.5 m/s 0.5% F.S. and 1.5% o.r.Operating temperature: 0 - 60°CCalibration standard:22°C / 960 hPa / 35% rHThe ThermoAir3 is our specialist instrument for measuring very small air flow and determining degree of turbulence. Relavite humidity can also be measured with the separate humidity sensor. The automatic temperature compensation, barometric pressure correction for local altitude, simple zero adjustment, individually adapted measuring sensors and our SCS wind tunnel guarantee high precision measurement and simple handling. Typical applications for this instrument are very small flow rate measurements in the lab., in clean rooms, air conditioning, drying and refrigeration installations, plus workplace comfort and well-being measurements.
No prices for category and customer group
ThermoAir 4 omnidirectional
No prices for category and customer group
Flow measuring ranges:0.015 to 1 m/sor 0.015 to 5 m/sHead size: 8 mmShaft: 15 mmProbe length: 300 mmAngle of flow: +- 180°Cable length: 1.5 m (more on requ.)Measurement accuracies:1 m/s 1.0% F.S. and 1.5% o.r.5 m/s 0.5% F.S. and 1.5% o.r.Operating temperature: 0 - 60°CCalibration standard:22°C / 960 hPa / 35% rHThe ThermoAir4 is our specialist instrument for measuring very small air flow and determining degree of turbulence. Relavite humidity can also be measured with the separate humidity sensor. The automatic temperature compensation, barometric pressure correction for local altitude, simple zero adjustment, individually adapted measuring sensors and our SCS wind tunnel guarantee high precision measurement and simple handling. Typical applications for this instrument are very small flow rate measurements in the lab., in clean rooms, air conditioning, drying and refrigeration installations, plus workplace comfort and well-being measurements.
No prices for category and customer group
ATEX-Anemometer
Ex ia I / Ex ia IIC T4
Schiltknecht MiniAir20 indication unit Ex ia I / Ex ia IIC T4
No prices for category and customer group
MiniAir20 indication unit Ex ia I / Ex ia IIC T4
Type a.640.20.Ex
I M2 Ex ia I Mb / II 2G Ex ia IIC T4 Gb
Automatic identification of probe and range for
flow, temperature, humidity measurements.
Average, minimum and maximum values can be called up.
Free choice of measuring time (2 s - 2 h)
with timer for repeat measurements.
Battery operated
No prices for category and customer group
MiniAir mini ATEX
No prices for category and customer group
MiniAir mini ATEX plastic/aluClassification II 2G EEx ia IIC T6 / I M2 EEX ia IThe mini ATEX probe made of plastic and aluminium is suitable to use it in the environment explosive substances. There are two different flow measuring ranges 0,4 to 20 m/s and 0,5 to 40 m/s. With a measuring accuracy of the flow of 1,0 % F.S. and 1,5 % o.r. is the use of a vane anemometer most exact measurement method. With an accuracy of +/-0,5°C is this probe able to measure temperatures from -20 to +140°C and you can use it in temperatures from -30 to +140°C.The cable is 2 m long and can be exposed to temperatures of 80 to 85°C.With the following measurements the mini is our middle snap head:head diameter 22 x 28 mm; probe length 175 mm The probe should be stored in temperatures from -65 to +150°C.By the snap head principle the probe is useable for a non stop operation and you can easily change the head.MiniAir mini ATEX stainless steel to 140°CClassification II 2G EEx ia IIC T6 / I M2 EEX ia IThe mini ATEX probe made of stainless steel is suitable to use it in the environment of explosive substances .There are two different flow measuring ranges 0,7 to 20 m/s and 0,8 to 40 m/s. With a measuring accuracy of the flow of 1,0 % F.S. and 2,0 % o.r. is the use of a vane anemometer most exact measurement method. With an accuracy of +/-0,5°C is this probe able to measure temperatures from -20 to +140°C and you can use it in temperatures from -30 to +140°C.The cable is 2 m long and can be exposed to temperatures of 80 to 85°C.With the following measurements the mini is our middle snap head:head diameter 22 x 28 mm; probe length 182 mm The probe should be stored in temperatures from -65 to +150°C.If required the head can be replaced by us.MiniAir mini ATEX stainless steel to 250°CClassification II 2G EEx ia IIC T6 / I M2 EEX ia IThe mini ATEX probe made of stainless steel is suitable to use it in the environment explosive substances .There are two different flow measuring ranges 0,7 to 20 m/s and 0,8 to 40 m/s. With a measuring accuracy of the flow of 1,0 % F.S. and 2,0 % o.r. is the use of a vane anemometer most exact measurement method. This probe does not have a temperature measurement. The probe is usable in temperatures from -30 to +250°C and the external electronic system in temperatures up to 65°C.The cable is 2,4 m long (1,5 m from the external electronic system) and can be exposed to a temperatures of 250°C.With the following measurements the mini is our middle snap head:head diameter 22 x 28 mm; probe length 182 mm The probe should be stored in temperatures from -65 to +250°C.The external electronic system and the cable should be stored in temperatures to max. 65°C.If required the head can be replaced by us.
No prices for category and customer group
MiniAir macro ATEX
No prices for category and customer group
MiniAir macro ATEX plastic/aluClassification II 2G EEx ia IIC T6 / I M2 EEX ia IThe MiniAir macro probe made of plastic and aluminium is suitable to use it in the environment of explosive/inflammatory substances. There is just one flow measuring range from 0,3 to 40 m/s. With a measuring accuracy of the flow of 1,0 % F.S. and 1,5 % o.r. is the use of a vane anemometer most exact measurement method. With an accuracy of +/-0,5°C is this probe able to measure temperatures from -20 to +140°C and you can use it in temperatures from -30 to +100°C.The cable is 2 m long and can be exposed to temperatures of 80 to 85°C.With the following measurements the macro is our biggest snap head:head diameter 85 x 80 mm; probe length 235 mm The probe should be stored in temperatures from -65 to +150°C.By the snap head principle the probe is useable for a non stop operation and you can easily change the head.MiniAir macro ATEX plastic/stainless steelClassification II 2G EEx ia IIC T6 / I M2 EEX ia IThe MiniAir macro probe made of plastic and stainless steel is suitable to use it in the environment of explosive/inflammatory substances. There is just one flow measuring range from 0,2 to 20 m/s. With a measuring accuracy of the flow of 1,0 % F.S. and 1,5 % o.r. is the use of a vane anemometer most exact measurement method. With an accuracy of +/-0,5°C is this probe able to measure temperatures from -20 to +140°C and you can use it in temperatures from -30 to +100°C.The cable is 2 m long and can be exposed to temperatures of 80 to 85°C.With the following measurements the macro is our biggest snap head:head diameter 85 x 80 mm; probe length 235 mmThe probe should be stored in temperatures from -65 to +150°C.By the snap head principle the probe is useable for a non stop operation and you can easily change the head.MiniAir macro ATEX alu/brassClassification II 2G EEx ia IIC T6 / I M2 EEX ia IThe MiniAir macro probe made of aluminium and brass is suitable to use it in the environment of explosive/inflammatory substances. There is just one flow measuring range from 0,2 to 20 m/s. With a measuring accuracy of the flow of 0,5 % F.S. and 1,5 % o.r. is the use of a vane anemometer most exact measurement method. With an accuracy of +/-0,5°C is this probe able to measure temperatures from -20 to +140°C and you can use it in temperatures from -30 to +100°C.The cable is 2 m long and can be exposed to temperatures of 80 to 85°C.With the following measurements the macro is our biggest snap head:head diameter 80 x 70 mm; probe length 235 mmThe probe should be stored in temperatures from -65 to +150°C.By the snap head principle the probe is useable for a non stop operation and you can easily change the head.
No prices for category and customer group