MiniAir64 mini 20 m/s (vane and handle in alu)

SFR 1,000.00*

Environmental Temparature
Measuring range
Vane and handle material
Product number: SW10050.5
Product information "MiniAir64 mini 20 m/s (vane and handle in alu)"
Process measuring device - linear current signal

MiniAir64 mini plastic/alu
The MiniAir64 mini made of plastic and aluminium is suitable to use it in the environment of non aggressive gas and fluids.
There are two different flow measuring ranges 0,4 to 20 m/s and0,5 to 40 m/s.
With a measuring  accuracy of the flow of 1,0 % F.S. and 1,5 % o.r. is the use of a vane anemometer most exact measurement method.
The probe is usable in temperatures from -10 to +80°C.
An external supply of 9 to 24 V DC is necessary for the electricity supply. 
The output signal of the probe is 4 to 20 mA.
The cable is 5 m long.

With the following measurements the mini is our middle snap head:
head diameter 22 x 28 mm; access opening 35 mm; probe length 175 mm
The probe should be stored in temperatures from -65 to +150°C.

Because of the snap head principle our probes are useable for a non-stop operation and the head is easily changeable.

MiniAir64 mini stainless steel 140°C
The MiniAir64 made of stainless steel is suitable to use it in the environment of non aggressive gas and fluids.
Here is just one flow measuring range from 0,7 to 20 m/s.
With a measuring  accuracy of the flow of 1,0 % F.S. and 2,0 % o.r. is the use of a vane anemometer most exact measurement method.
The probe is usable in temperatures from -10 to +80°C.
An external supply of 9 to 24 V DC is necessary for the electricity supply.
The output signal of the probe is 4 to 20 mA.
The cable is 5 m long.

With the following measurements the micro is our middle probe head:
head diameter 22 x 28 mm; access opening 35 mm; probe length 175 mm
The probe should be stored in temperatures from -65 to +150°C.
If required the head can be replaced by us.


MiniAir64 mini stainless steel 250°C
The MiniAir64 mini made of stainless steel is suitable to use it in the environment of non aggressive gas and fluids.
There are two different flow measuring ranges 0,7 to 20 m/s and 0,8 to 40 m/s.
With a measuring  accuracy of the flow of 1,0 % F.S. and 2,0 % o.r. is the use of a vane anemometer most exact measurement method.
The probe is usable in temperatures from -10 to +80°C.
An external supply of 9 to 24 V DC is necessary for the electricity supply.
The output signal of the probe is 4 to 20 mA.
The cable is 5 m long.

With the following measurements the micro is our middle probe head:
head diameter 22 x 28 mm; access opening 35 mm; probe length 175 mm
The probe should be stored in temperatures from -65 to +150°C.

If required the head can be replaced by us.